INFORMATION & PROJECT PLANNINGExplore the range · no online orders or payments

Greatbridge Key Clamp

Make it fit your space

Choose an example, enter your measurements and review the kit.

A layout and take-off for review. Structural suitability, stock, exact connections, cuts and prices require approval. Live purchasing is disabled.

Shop individual fittings
Illustrative starter — not your draft

Example only · your measurements stay blank. Supply approvals remain held.

Dimensioned isometric Key Clamp layoutThe same entered run lengths, post stations, rail heights, corners and slope are projected in three dimensions. Height to top of rail (mm): 1100 mm. P labels identify posts and F labels identify fitting locations when detailed part labels are enabled or a part is selected. Fittings and base locations are schematic; socket geometry, bolt patterns and exact cuts remain held. All drawing objects are also available in the accessible object list.ISOMETRIC — your entered arrangementGross tube geometry · schematic fitting / fixing locationsPost P1 · run 1 · 0 mm from run start: mounting centre only. Exact fixing pattern held.Post P2 · run 1 · 1500 mm from run start: mounting centre only. Exact fixing pattern held.Post P3 · run 1 · 3000 mm from run start: mounting centre only. Exact fixing pattern held.Post P4 · run 1 · 4500 mm from run start: mounting centre only. Exact fixing pattern held.Post P5 · run 1 · 6000 mm from run start: mounting centre only. Exact fixing pattern held.1100 mmRun 1 · 6000 mm horizontal planRun 1 · 6000 mm plan4 × 1500 mm centresRequested run and height datums · schematic fitting / fixing locationsDimensioned isometric Key Clamp layoutThe same entered run lengths, post stations, rail heights, corners and slope are projected in three dimensions. Height to top of rail (mm): 1100 mm. P labels identify posts and F labels identify fitting locations when detailed part labels are enabled or a part is selected. Fittings and base locations are schematic; socket geometry, bolt patterns and exact cuts remain held. All drawing objects are also available in the accessible object list.ISOMETRIC — your entered arrangementGross tube geometry · schematic fitting / fixing locationsPost P1 · run 1 · 0 mm from run start: mounting centre only. Exact fixing pattern held.Post P2 · run 1 · 1500 mm from run start: mounting centre only. Exact fixing pattern held.Post P3 · run 1 · 3000 mm from run start: mounting centre only. Exact fixing pattern held.Post P4 · run 1 · 4500 mm from run start: mounting centre only. Exact fixing pattern held.Post P5 · run 1 · 6000 mm from run start: mounting centre only. Exact fixing pattern held.1100 mmRun 1 · 6000 mm horizontal planRun 1 · 6000 mm plan4 × 1500 mm centres
GB
Loading 3D; your dimensioned arrangement remains available.

Orange demonstration tube · sold separately.

Model options & parts
CAD and connection notes

Silver or coated fitting appearance follows the exact selected CAD model; no physical GB mark is added. Exact fitting placement is checked separately from tube layout. Nominal tube illustrates gross layout. Stock, socket deductions and manufacture require separate authority.

Accessible arrangement parts and dimensions
Run 1: 6000 mm plan
Post/support centres; horizontal plan run
4 × 1500 mm centres
Actual post/support centre spacing
1100 mm · Height to top of rail (mm)
Height to top of rail (mm)

0 uprights / supports · 0 bays · Ø… mm request

1. Start with an example

Examples show a requested layout, not an approved guarding design. Choosing another replaces this working draft; Undo restores it.

Your measurements
Tube, finish, rails & mounting
Upright positions & other layouts

Calculated positions follow edits until you keep them or add the kit to basket. Kept/custom positions never move automatically.

Site details & notes
Technical & commercial holds (11)
  • Retained fitting candidates are not approved system designs. Exact product application, socket depths, fitting dimensions and connection geometry require verification.
  • No approved tube product, wall thickness, finish capability or stock length is recorded. Tube totals are gross geometric requirements only; stock optimisation, offcuts, waste and purchasing are held.
  • No tube product is active in the customer catalogue. Gross tube requirements are retained; no inactive product is selected or exposed.
  • Confirm substrate, anchor type, diameter, quantity, embedment, edge distances, drill size and installation method. No fixings or generic upsells were inferred.
  • Fitting and tube availability, prices, carriage and handling require a Greatbridge commercial revision. Price on review; purchase and release unavailable.
  • End-post rail connection: no single verified retained product is selected. Confirm the short tee socket directions, rail height and end-post arrangement.
  • Intermediate-post rail connection: no single verified retained product is selected. Choose the exact tee or cross after checking which tubes continue through each socket. The layout does not approve a connection design.
  • Choose stock lengths to cut on site, or a cut, deburred, labelled and bundled kit.
  • An approved tube product and actual stock lengths are required. No supplier SKU or material price has been invented.
  • The fitting arrangement and connection directions need verified compatibility evidence. The customer does not need to choose an engineering deduction.
  • Material, cutting, delivery and VAT charges remain on review. Price on review; no rate is offered.